ASLI | Across International Market ● Expand International Business Professional Brand of Ventilation Fittings
Home
About Us
Company Profile
Development History
Certificate
Industry Solutions
Classification by Function
Classification by Application Field
Headquarters Laboratory
Case
Hotels, Office Buildings
Schools, Hospitals, Supermarkets
Industrial Plant
Contact Us
Contact Details
Online Message
语言切换
简体中文
English
Product Center
Air Outlet
Air Supply Vent
Normal Air Supply
Large Space Air Supply
Special Vent
Temperature Controlled Air Supply Vent
Electric Air Supply Vent
Anti-condensation Vent
Lighting Type Air Outlet
Replacement Air Outlet
Floor Type Air Outlet
Return Air Vent
Exhaust Vent
Positive Pressure Air Supply Vent
Valves
Air Valve
Constant Air Volume Valve
Manual Valve
Electric Valve
Ordinary Electric Valve
Airtight Electric Valve
Check Valve
Other
Inspection Port
Residual Pressure Valve
Inspection Door
CCCF Fire Valve
Fire Damper
Smoke Exhaust Fire Damper
Smoke Exhaust Valve
SDc
SDj
Multi-leaf Smoke Exhaust Port
Plate Type Smoke Exhaust Port
UL Valve
UL Fire Damper
UL Smoke Exhaust Fire Damper
UL Smoke Exhaust Valve
Silencing Type
Silencer Air Duct
Muffler
Silencer Elbow
Silent Static Pressure Box
Silent Louvers
Hose
Material model: CWZ-A aluminum plate Surface treatment: CWZ-A powder coating Structural overview: ● A temperature-sensing actuator is installed at the neck of the air outlet, which can automatically sense the air flow temperature and drive the inner nozzle to change the air supply angle ● When the summer air supply temperature is ≦17℃, the air flow is blown out horizontally ● When the winter air supply temperature is ≧27℃, the air flow is blown out in an oblique downward direction ● It can meet the air supply requirements under winter and summer conditions ● The temperature-sensing actuator does not require manual or power supply and electronic control equipment
Material model: XLZ-A aluminum plate Surface treatment: XLZ-A powder coating Structural overview: ● A temperature-sensing actuator is installed at the neck of the air outlet, which can automatically sense the air flow temperature and drive the inner blades to change the air supply angle under different air supply conditions ● In summer, the air supply temperature is ≦17℃, the blades move down, and the air flow is blown out horizontally ● In winter, the air supply temperature is ≧27℃, the blades move up, and the air flow is blown out vertically ● It can meet the air supply requirements under winter and summer conditions ● The temperature-sensing actuator does not require manual or power supply and electronic control equipment
Material model: CGZ-T iron plate Surface treatment: CGZ-T powder coating Structural overview: ● A temperature-sensing actuator is installed on the nozzle neck, which can automatically sense the air flow temperature and drive the overall nozzle to change the air supply angle ● When the summer air supply temperature is ≤17℃, the air flow is blown out horizontally ● When the winter air supply temperature is ≥27℃, the air flow is blown out in an oblique downward direction ● It can meet the air supply requirements under winter and summer conditions ● The temperature-sensing actuator does not require manual or power supply and electronic control equipment
Material model: CAZ-A aluminum plate Surface treatment: CAZ-A powder coating Structural overview: ● The diffuser neck is equipped with a temperature-sensing actuator, which can automatically sense the airflow temperature and drive the inner blades to move up and down under different air supply conditions, and automatically adjust the air supply direction ● In summer, the air supply temperature is ≦17℃, the blades move down, and the airflow is horizontally attached and diffused ● In winter, the air supply temperature is ≧27℃, the blades move up, and the airflow is vertically sent down ● It can meet the air supply requirements under winter and summer conditions ● The temperature-sensing actuator does not require manual or power supply and electronic control equipment
Material model: CPZ-A aluminum plate Surface treatment: CPZ-A powder coating Structural overview: ● The diffuser neck is equipped with a temperature-sensing actuator, which can automatically sense the airflow temperature and drive the inner blades to move up and down under different air supply conditions, and automatically adjust the air supply direction ● In summer, the air supply temperature is ≦17℃, the blades move down, and the airflow is horizontally attached and diffused ● In winter, the air supply temperature is ≧27℃, the blades move up, and the airflow is vertically sent down ● It can meet the air supply requirements under winter and summer conditions ● The temperature-sensing actuator does not require manual or power supply and electronic control equipment
Material model: DAZ-A aluminum plate Surface treatment: DAZ-A powder coating Structural overview: ● A temperature-sensing actuator is installed on the neck of the diffuser, which can automatically sense the airflow temperature and drive the inner blades to move up and down under different air supply conditions, and automatically adjust the air supply direction ● In summer, the air supply temperature is ≦17℃, the blades move down, and the airflow is horizontally attached and diffused ● In winter, the air supply temperature is ≧27℃℃, the blades move up, and the airflow is vertically sent down ● It can meet the air supply requirements under winter and summer conditions ● The temperature-sensing actuator does not require manual or power supply and electronic control equipment